This is default featured slide 1 title

Go to Blogger edit html and find these sentences.Now replace these sentences with your own descriptions.This theme is Bloggerized by Lasantha Bandara - Premiumbloggertemplates.com.

This is default featured slide 2 title

Go to Blogger edit html and find these sentences.Now replace these sentences with your own descriptions.This theme is Bloggerized by Lasantha Bandara - Premiumbloggertemplates.com.

This is default featured slide 3 title

Go to Blogger edit html and find these sentences.Now replace these sentences with your own descriptions.This theme is Bloggerized by Lasantha Bandara - Premiumbloggertemplates.com.

This is default featured slide 4 title

Go to Blogger edit html and find these sentences.Now replace these sentences with your own descriptions.This theme is Bloggerized by Lasantha Bandara - Premiumbloggertemplates.com.

This is default featured slide 5 title

Go to Blogger edit html and find these sentences.Now replace these sentences with your own descriptions.This theme is Bloggerized by Lasantha Bandara - Premiumbloggertemplates.com.

sâmbătă, 10 aprilie 2010

Dispozitiv cu ultrasunete impotriva rozatoarelor

Aparatul cu ultrasunete este ideal pentru a indeparta rozatoare: soareci, sobolani, dihori, etc... (suprafata inte 100 si 300mp). Ultrasunetele nu sunt percepute de oameni si nici nu deranjeaza animalele sau pasari de curte. Rozatoarele sesizeaza rapid ultrasunetele ca pe un semnal de alarma (le irita auzul, sistemul nervos) si sunt obligate sa paraseasca acel spatiu. Aceste aparate se foloseste si preventiv, pentru a nu patrunde rozatoare in anumite spatii.

miercuri, 7 aprilie 2010

Descarcatoare de supratensiuni tranzitorii SPD


SPD - Surge Protective Devices - se impart in doua categorii : pt. instalatii
electrice de curent alternativ - ele fac subiectul acestei pagini - si pt. retele
de telecomunicatii(telefonie, pc network, radiocomunicatii).
Trei clase de protectie definesc dispozitivele pentru supratensiuni tranzitorii
in instalatiile electrice de joasa tensiune - clasa 'ntaia, clasa 'doua si clasa 'treia -,
raportate la indicii keraunici si la fenomenele orajoase.
SPD clasa 'ntaia se instaleaza, de obicei, pt. contracararea loviturilor de fulger
directe - impulsuri de mare intensitate -, acolo unde exista sisteme de protectie
la fulger(LPS - Lightning Protection System) sau paratraznete; ca utilizator
casnic, doar de nu stai in varfu' dealului, nu prea ai nevoie de ele.
Clasa a doua e de baza in apartament urmata de a treia pt. fine tuning -
intalnita si in prelungitorul de alimentare ori direct in aparat.
SPD-ul contine un MOV - Metal(zinc)-Oxide Varistor - ce asigura o capacitate
mare de descarcare in timp scurt(<25ns); acest varistor(variable resistor,
non-ohmic, numit si VDR - Voltage Dependent Resistor) se duce intr-un timp
invers proportional cu intensitatea si numarul varfurilor de tensiune/curent
descarcate in pamant; va sa zica, cand se duce, ca se pune in scurtcircuit si,
prin urmare, instalatia electrica trebuie protejata de el - se inseriaza SPD-ul
cu sigurante fuzibile sau MCB specificate de producator; de obicei, pt. un
apartament (prea)traznit, MCB-ul asociat este un 2P de 20A; spre deosebire de
celelalte protectii din panoul electric de apartament, legate in serie cu instalatia,
SPD-ul este pus in paralel pe circuitele electrice si instalatia electrica merge in
continuare si cu dispozitivul dus, dar dispare functia de protectie la varfuri
tranzitorii; momentul defectarii este semnalizat mecanic sau electric pe partea
frontala a SPD-ului, dar cel mai bine se urmareste cu regularitate MCB-ul sarit.
Varistorul consumabil este inclus intr-un cartus debrosabil ce se inlocuieste
cu unul de acelasi tip(caracteristici, firma) fara a interveni in vreun fel asupra
bazei modulare a dispozitivului montata pe sina DIN.
 
Urmatorii parametrii se au in vedere la achizitionarea SPD-ului clasa 2-a :
Curentul nominal In = varful de curent ce poate fi descarcat in mod repetat
(15 - 20 de ori) inainte ca dispozitivul de protectie(cartusul detasabil), sa
ajunga la gunoi; are valori uzuale de 2...20kA; impreuna cu In se defineste si
Im = varful maxim de curent non-repetitiv, fara ca SPD-ul sa mai poata
fi folosit ulterior ; este de 8...65kA(de 2...4 ori In);
Tensiunea de lucru Uc = valoarea eficace a tensiunii aplicate continuu lui
lui SPD a.i curentul prin varistor sa ramana neglijabil; uzual ea are valoarea
retelei monofazate(max.255V) si nu poate depasi 275V pt. mai mult de 5 sec.;
Tensiunea de protectie Up = marimea pt. care se construieste, de fapt,
SPD-ul - in corelatie cu supratensiunile tranzitorii; are valori standard intre
1kV si 2,5kV(kilovolti, mii de volti).
Acasa-i potrivit un SPD 1P+N clasa '2-a cu Im cel mult 20kA si Up de max. 1,5kV.

Discriminarea se realizeaza natural prin lungimea minima a conductoarelor
(10m) intre dispozitive sau fortat cu bobina soc pt. declansare controlata.
Pentru ca protectia sa fie eficace, la instalarea SPD-ului se respecta o regula,
a celor maxim 50cm ai lungimii cablurilor ce unesc SPD-ul si MCB-ul asociat
lui de la intrarea in tablou pana la impamantare.
Standardele IEC asociate dispozitivelor de protectie la supratensiuni de
tranzitie, conform clasei 2 de test (8/20ms - 8 microsecunde timp de crestere
a impulsului respectiv 20ms timp de revenire) sunt : EN61643-11 pt. Europa
si IEC61643-1 international.

Intrerupatoare diferentiale RCD

Ce alegem singuri pt. domiciliul personal, din cauza vanzatoarei cu alibi blond ?
RCD-ul se construieste standard, ca si MCB-ul, pt. montarea usoara pe aceeasi
sina metalica DIN, in multipli de module(18±0,5mm) sau pasi(9±0,25mm).

Caracteristica principala a RCD este sensibilitatea - valoarea curentului
rezidual la care dispozitivul taie circuitul : 10/30mA pt. protectia la contactul
direct cu conductorul, 100mA in cazul contactului indirect(printr-o rezistenta
de izolatie intermediara), 300/500mA - inutil la electrocutare dar ideal pt.
protectia la foc ; in unele situatii, focul se aprinde la un curent de defect de doar
1A, valoare la care intrerupatorul automat MCB este de-a dreptul ne-simtitor.
Pentru socul electric cel de toate zilele este optima valoarea de 30mA, tot ea
buna si la acoperirea curentilor reziduali de repaus prin izolatia defectuoasa,
ne-inca-periculoasa, de ordinul miliamperilor, anulati din valoarea sensibilitatii
RCD-ului; acesti curenti, la fel ca si cei generati de
balastul electronic al lampilor fluorescente compacte
CFL, pot duce la declansari intamplatoare, chiar cu
toate imunitatile garantate de producator.

In functie de felul curentului pe care actioneaza, avem RCD clasa AC pt. curent
numai alternativ, clasa A pt. curent alternativ sau curent continuu pulsatoriu
(ex: scule electrice de mana) si clasa B pt. curentul continuu pur; clasele AC si A
se pot pune fara retinere in cocioaba.

Curentul nominal este important in selectia RCD-ului, dar are o poveste cu
putin cantec pentru cele doua tipuri de RCD.

In cazul RCCB (contactor electromecanic comandat de un circuit diferential),
curentul nominal In se refera la capabilitatea de curent a contactorului;
din cauza asta, RCCB-ul se alege cu In mai mare decat al intrerupatoarelor
automate MCB din instalatie - daca intrerupatorul general MCB are 32A, se ia
RCCB de 40A; pe alta cale spus, RCCB sare numai la atingerea sensibilitatii de
30mA nu si la valorea nominala de 40A.
La RCBO(MCB+RCD, acelasi pol protejat simultan magneto-termic si diferential)
curentul nominal e cel la care MCB-ul din el declanseaza in cazul unei suprasarcini;
RCBO sare, asadar, in doua situatii : la depasirea sensibilitatii RCD-ului intern(30mA)
sau la depasirea curentului nominal - de 10, 16 sau 32A - al MCB-ului propriu; la
un RCBO se au in vedere toate caracteristicile MCB-urilor (curba, rupere, ...).

La RCD se face coordonare/discriminare putin diferit de cea a MCB ; pt. asta
exista RCD tip S(selectiv, cu delay); daca vrei si protectie suplimentara la
incendiu pt. toata instalatia, la curenti mici de defect(1A, cum ziseram mai la
deal), n-ai decat sa pui un RCCB bipolar tip S in capu' instalatiei, cu
sensibilitate de 300mA si curent nominal de 40A.

Doua cuvintele si gata : RCD-urile au pe ele un buton de test ce trebuie apasat
cu regularitate - lunar; desi se numesc bipolare, RCCB-urile au Nulul marcat
cu N(in stilul MCB-urilor 1P+N); standardele IEC asociate lor - dupa care le
deosebesti cel mai usor - sunt EN61008 pt. RCCB, EN61009 pt. RCBO si cel
comun, pt. capacitatea de rupere - EN60947 ; e just sa ai RCD prin preajma
dar nu chiar in orice situatie: aparatura medicala tip life support, atunci
cand n-are back-up, se alimenteaza din prize neprotejate de RCD-uri ce
pot avea, ca orice medicament facut de mana omului, doua taisuri......

Intrerupatoare automate MCB

Latimea intrerupatoarelor automate e standard, masurata in multipli de
module(18±0,5mm) sau pasi(9±0,25 mm) - 1P are 2 pasi(18mm), la fel si
1P+N, iar 2P este lat de 4 pasi(36mm).
Adesea, ceea ce nu stii nu te baga in bucluc mai mult decat ceea ce crezi ca stii
bine dar, de fapt, e eronat; ca sa nu te joace vanzatorul cum vrea muschii lui,
poti face diferenta intre 1P, 1P+N si 2P dintr-o privire, asa cum e f. clar in poza :
1P are o intrare(surub de prindere) si o iesire pe cand 1P+N are, pe aceeasi
latime, si sus si jos, cate doua suruburi; intre 1P+N si 2P nu ai cum sa ratezi.
Tot in poza se vad simbolurile inscriptionate pe carcasa intrerupatoarelor :
legate intre ele, de jos in sus, un semicerc(protectia la scurtcircuit, magnetica),
un (semi)dreptunghi(protectia la suprasarcina, termica) si linia oblica
(intrerupatorul mecanic); unul sau ambele simboluri de jos pot lipsi
si ramane doar intrerupatorul gol-golut, cum este cel de pe Nulul lui 1P+N.

Trei caracteristici electrice sunt importante cand dam banii pe intrerupatorul
automat MCB, toate trei inscrise pe partea frontala a dispozitivului :

Curentul nominal - cel la care ne referim cand spunem siguranta de 10A ;
el reprezinta valoarea de protectie a cablurilor din pereti, limita de jos a
suprasarcinii - valoare a curentului nominal la depasirea careia intrerupatorul
declanseaza, taind circuitul; uzual, se alege de 10A pt. lumini, 16A pt. prize
si, pt. o discriminare(coordonare) corecta - intrerupatoarele din aval cad
mereu inaintea celor din amonte -, 32A pt. intrerupatorul general;

Capacitatea de rupere aka curentul maxim de scurtcircuit rupt(intrerupt) de
contactele intrerupatorului fara distrugerea lor a.i. MCB-ul sa mai poata fi folosit
ulterior; acasa este recomandata la 4,5kA sau 6kA(kiloamperi, mii de amperi);

Curba de declansare - asa cum masina papa benzina, la demaraj, de cateva
ori cantitatea medie pt. croaziera, tot asa unele aparate electrice trag de la
priza, la pornire, un curent de 3 ... 14 ori mai mare decat cel nominal, curent
ce trebuie suportat, pt. scurt timp, de intrerupatorul automat fara intreruperea
circuitului - aceasta proprietate imparte intrerupatoarele in diverse clase de
functionare asociate unor functii sau curbe : de la B - aparate usoare, via C -
nici asa, nici altminteri - pana la D pt. instalatii greoaie ; C este curba de casa.

Cand vezi pe dispozitiv : C16(sau 10 ori 32) , 4500A(sau 4500 in chenar negru
ori 4,5kA) , ~230V 50Hz - insemnand curba C, 16A curent nominal, 4,5kA
capacitate de rupere si retea monofazata de 230V/50Hz -, atunci ai facut o
alegere corecta.

Logica vulcaniana sugereaza ca intrerupatoarele bipolare 2P sunt ideale pt.
orice circuit din oricare locuinta, dar o varianta minimala ca spatiu, fara rabat
la protectia instalatiei si siguranta chiriasului mester amator, e montarea de
intrerupatoare 1P+N pt. lumini si prize si un intrerupator automat general 2P.

marți, 6 aprilie 2010

AM PRIMIT CATEVA NELAMURIRI DIN PARTEA UNUI CITITOR

AM PRIMIT CATEVA NELAMURIRI DIN PARTEA UNUI CITITOR...SI VOI INCERCA SA FIU EXPLICIT IN LEGATURA CU O POSTARE MAI VECHE


ABC, Comtec, Gewis, Hager, Legrand, Merlin Gerin , Moeller, Shrack - sunt producatori de disjunctoare magneto termice. Deci ai de unde alege. Le-am pus in ordine alfabetica, nu neaparat a calitatii lor. Important este sa nu iei contrafacute cu putini bani. Si pretul lor iti spun calitatea.


Cat de utila credeti ca este conectarea unui diferential?

Italienii le spun acestor diferentiale "salva vita" E foarte usor de observat ca tradus ar veni "salveaza viata" Cred ca iti spune totul cat de utile sunt .....Eu unul intodeauna recomand montarea lor. Dealtfel BMP-urile au diefrentiale in ele.

Cat despre curenti, am avut undeva prin caiete un tabel cu senzatiile si influentele la anumiti curenti parcursi prin corp.

O conditie ca diferentiala sa lucreze este ca circuitul de curent sa fie intre faza si pamant prin atingeri directe sau indirecte. La electrocutarile intre faza si nul, (izolat fata de pamant) diferentiala nu va lucra....



 Spun asta nu pentru a face cursuri de electrotehnica cu VOI ci doar mi-am amintit ca un client odat m-a sunat indignat ca desi a avut montata o diferentiala ca si protectie cand a umblat la priza s-a electrocutat de a vazut stele verzi si siguranta nu a declansat. I-am cerut sa apese butonul de test si siguranta a declansat. I-am spus ca siguranta functioneaza corect si in situatia asta, probabil ca s-a electrocutat intre faza si nul, si ultrior a recunoscut ca a atins intre faza si nul.  


Si ce mi-a mai venit acum in minte si cred ca e important sa iti spun tinand cont ca e destul de scumpa : daca vrei sa pui sig diferentiala, pe general poti sa o pui, cred, fara nici o problema. Daca vrei sa o pui pe doar un circuit anume, trebuie sa fii sigur ca instalatia in aval este facuta corect. In sensul ca nu s-a " imprumutat " pe traseu ptr iluminat doar nulul de la priza sau invers sau doar faza de iluminat de la priza sau invers. De ex daca pe faza ei trece un curent de 7 A si ptr. ca priza de la bucatarie are nulul luat de pe circ de la bec. Inapoi ii va veni pe nulul diferentialei 7A - 2.5 A cat ai pe priza respectiva ( caci cei 2,5 A se vor intoarce pe nulul de la circuitul de iluminat) deci cca 4,5 A. Dezechilibrul acesta ( pleaca 7A si se intorc 4,5 A ) o va sesiza imediat dieferentiala si va declansa. Ea orice dezechilibru mai mare de 0.03 A o va sesiza si va declansa
Am spus asta caci tot asa am intalnit o situatie de genul acesta. Omul in vointa de-asi spori siguranta si-a cumparat-o diferentiala, si-a montat-o pe circuitul de prize si nu reusea sa o conecteze. Cum o conecta - declansa. Dupa ce cei de la magazin l-au asigurat ca nu e defecta. M-a solicitat sa ii rezolv situatia si am gasit un "imprumut" de genul de mai sus care tot ii declansa sig.

La cineva caruia i-am montat o diferential ptr o incapere de unde erau masina de spalat rufe , masa de calcat. Si cand menajera calca tot ii sarea diferentiala. A trebuit sa le explic caci fierul de calcat cu aburi este defect si trebuie inlocuit. Eu altceva nu am ce sa fac S-a rezolvat imediat cum au cumparat un fier nou. 


O alta situatie cand am pus o diferentiala intr-o bucatarie unde avea si masina de spalat rufe automata(mai veche) si declansa diferentiala intempestiv . A trebuit sa le explic si lor caci masina este problema si este un semnal de alarma ca e o problema cu ea. Nu au vrut nicicum sa renunte la ea ci acceptau ideea sa renunte la un element ce costa 150 lei si sa le pun o siuranta simpla, decat sa-si cumpere un produs nou ce costa peste 1000 lei. Dupa multe negocieri am deschis masina si am vazut caci se prelingea apa. Dupa ce s-a rezolvat aceasta problema nu a mai declansat. 

Cred ca v-am "imbatat' de cap. Dar sper sa v fie de folos....